    No Load And Load Loss Test Transformer Test Bench IEC 60076 Standard


    Full Automatic Transformer Testing Equipment No-load and Load Loss Test Transformer Test Panel Test board

    IEC 60076

    Product Description
    Introduction of system composing and technical parameters
    1 To satisfy three-phase, one-phase measurement, transformer no-load and load should come to the following requirements:
    Voltage measuring range: 0~650V, current measuring range: 10mA~2A,
    Accuracy: 0.2 class; power: U*I, Accuracy: 0.2 class;
    Power factor: 0.050~1.000,accuracy: 0.2 class;
    Frequency: 40—70Hz, accuracy: 0.1 class; three-phase total power P;
    No-load current I.%,No-load loss P.;
    Load loss PK,impedance voltage UK;
    Three frequency Pa(Pab),Pb,Pc(Pbc);
    Average three-phase line voltage Un;
    Average three-phase current In. (including 19 harmonic wave analysis)
    2. High-voltage precision current transformer should meet
    the following requirements:
    Rated operation voltage: 3kV
    Withstand voltage:4kV
    Capacity: 1VA
    Measuring range: 0.1A~200A;
    Accuracy: 0.05 class
    The ratios are 200A,100A,50A,25A,10A,5A,2.5A/1A, total 7 steps.
    3. High precision Voltage transformer should meet the
    following requirements:
    Rated operation voltage: 3kV
    Withstand voltage: 4kV
    Capacity: 1VA
    Measuring range: 0.01kV~3kV;
    Accuracy: 0.05 class;
    The ratios are 3kV,2kV,1kV,0.5kV/0.1kV, total 4 steps. 7
    4. 250kVA three-phase voltage regulator should meet the
    following requirements:
    Capacity;250kVA
    Input voltage:380V
    Output voltage:20-650V
    Max load current: 222A
    When the input voltage is steady,the voltage regulator can stepless and smoothly adjust the output voltage.
    Technical Parameters:
    Item
    Scope of Measurement
    Relative Error
    Voltage
    0.1-800V
    ±(0.2% reading + 0.1% range)
    Current
    0.1-300A
    ±(0.2% reading + 0.1% range)
    Power
    U*I
    ±(0.2% reading + 0.1% range)
    Power factor
    0.1-0.9999
    ±3 figures
    Power supply
    AC 380V±10% 50Hz±2%
    Operating condition
    Working temperature: -20℃-40℃ Relative humidity <90%
    Outline dimension
    Customization
    Weight
    Customization